Ethernet / DMX operation
Options “Ethernet/DMX” has to be selected from the “Ethernet Mode” menu on the rst xture (connected to
the Ethernet) in the xture chain,next xtures have standard DMX setting.
Connect the Ethernet-input of the rst xture in the data chain with the network. Connect the DMX output of
this xture with the input of the next xture until all xtures are connected to the DMX chain.
Caution: At the last xture, the DMX chain has to be terminated with a terminator. Solder a 120 Ω resistor
between Signal (–) and Signal (+) into a XLR-plug and connect it in the DMX-output of the last xture.
Example:
DMX address=1 DMX address=23 DMX address=46
IP addres=002.168.002.002
Universe=0
DMX address=1 DMX address=23 DMX address=46
IP addres=002.168.002.003
Universe=1