Robe Robin CycFX 8 wireless DMX CRMX Dokumentacja Strona 6

  • Pobierz
  • Dodaj do moich podręczników
  • Drukuj
  • Strona
    / 29
  • Spis treści
  • BOOKMARKI
  • Oceniono. / 5. Na podstawie oceny klientów
Przeglądanie stron 5
Robin CycFX 8
6
Caution: Fixtures may cause severe injuries when crashing down! If you have doubts concerning the safety of a
possible installation, do not install the device and consult installation with an expert.
Tilt position concerning DMX values is shown on the picture below.
3.2 Connection to the mains
Fixtures must be installed by a qualified electrician in accordance with all national
and local electrical and construction codes and regulations.
Install a suitable plug on the power cord, note that the cores in the power cord are colored according to the
following table.
C
ore
(Eu)
C
ore
(US)
Connection
Plug Terminal Marking
Brown
Black
Live
L
Light blue
White
Neutral
N
Yellow/Green Green Earth
This device falls under class one and must be grounded!
Design of the Robin CycFX 8 allows to connect several fixtures to AC mains power in one interconnected daisy
chain using power input and throughput connectors. Needed daisy chain cords are stated in the chapter
“Technical specifications “
The max. number of connected fixtures depends on the AC mains power voltage:
15 fixtures at power supply= 230V
7 fixtures at power supply= 120V
6 fixtures at power supply=100V
Do not overload the supply line and the connecting leads.
3.3 DMX 512 connection
The fixture is equipped with 3-pin and 5-pin XLR connectors for DMX input/output.
Only use a shielded twisted-
pair cable designed for RS-485 and 3-pin/5-pin XLR- connectors in order to connect the controller with the fixture
or one fixture with another.
Wiring of the XLR connectors:
DMX input DMX output
XLR socket (rear view): XLR plug (rear view):
1
– Shield
2
- Signal (-)
3
- Signal (+)
4
– Not connected
5
– Not connected
Przeglądanie stron 5